Experimental results of pulse parameters and control rod worth measurements at TRIGA Mark II reactor in Ljubljana are presented. The measurements were performed with a completely fresh, uniform, and compact core. Only standard fuel elements with 12 wt% uranium were used. Special efforts were made to get reliable and accurate results at well-defined experimental conditions, and it is proposed to use the results as a benchmark test case for TRIGA reactors.