To apply fast and accurate simulation techniques to Taiwanese nuclear power plants, plant analyzer technology was transferred to Taiwan from the Brookhaven National Laboratory (BNL) through a cooperative program. The Chinshan plant analyzer is developed on the AD100 peripheral processor systems, based on the BNL boiling water reactor plant analyzer. The BNL plant analyzer was first converted from MPS10 programming for AD10 to ADSIM programming for AD100. It was then modified for the Taiwan Power Company’s Chinshan power station. The simulation speed of the Chinshan plant analyzer is eight times faster than real time. A load rejection transient performed at 100% of full power during startup tests was simulated with the Chinshan plant analyzer, and the results were benchmarked against test data. The comparison shows good agreement between calculated results and test data.