ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2026 ANS Annual Conference
May 31–June 3, 2026
Denver, CO|Sheraton Denver
Latest Magazine Issues
Mar 2026
Jan 2026
Latest Journal Issues
Nuclear Science and Engineering
April 2026
Nuclear Technology
February 2026
Fusion Science and Technology
Latest News
TerraPower announces second Ac-225 production facility
TerraPower Isotopes, a TerraPower subsidiary, plans to increase its actinium-225 production 20-fold by opening a new manufacturing facility in Philadelphia, Pa., and by expanding the capacity of its Everett, Wash., facility. On March 17, TerraPower Isotopes said it expects the new facility to begin producing the medical radioisotope for targeted alpha therapy in 2029.
Ahmad M. Ibrahim, Douglas E. Peplow, Joshua L. Peterson, Robert E. Grove
Fusion Science and Technology | Volume 68 | Number 3 | October 2015 | Pages 700-704
Technical Paper | Proceedings of TOFE-2014 | doi.org/10.13182/FST15-123
Articles are hosted by Taylor and Francis Online.
The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid Monte Carlo (MC)/deterministic radiation transport method was proposed to speed up the shutdown dose rate (SDDR) neutron MC calculation using an importance function that represents the neutron importance to the final SDDR. In this work, the MS-CADIS method was applied to the ITER SDDR benchmark problem. The MS-CADIS method was also used to calculate the SDDR uncertainty resulting from uncertainties in the MC neutron calculation and to determine the degree of undersampling in SDDR calculations because of the limited ability of the MC method to tally detailed spatial and energy distributions. The analysis that used the ITER benchmark problem compared the efficiency of the MS-CADIS method to the traditional approach of using global MC variance reduction techniques for speeding up SDDR neutron MC calculation. Compared to the standard Forward-Weighted-CADIS (FW-CADIS) method, the MS-CADIS method increased the efficiency of the SDDR neutron MC calculation by 69%. The MS-CADIS method also increased the fraction of nonzero scoring mesh tally elements in the space-energy regions of high importance to the final SDDR.